Added to cart
AcidicTank Approved

CoreKleen

Radiators and cores, back to bare metal

Protein soils and mineral scale — dissolved out of passages nothing mechanical reaches.

pH 1 — dissolves scale nothing else touchesEvery core passage cleaned simultaneouslyProtein + scale in one immersion
Pricing on application — trade accounts
corekleen container
Machined steel components in a stainless mesh basket being lowered into an ultrasonic cleaning bath
The chemistry is half the process. It wets the tank and the part so cavitation can form at the surface, and it holds the soil once the ultrasound has lifted it.Illustration generated by Misonics.
Why It Wins

Radiators and cores, back to bare metal

A radiator core is hundreds of parallel passages a millimetre wide — unreachable by brush, ruined by rod, and progressively strangled by scale on the water side and grime on the air side. CoreKleen's strong acid chemistry (pH 1) dissolves what blocks them: mineral scale, corrosion products, and the protein soils food-plant and agricultural work bake on.

Cores immerse whole, chemistry reaches every passage simultaneously, and flow returns to specification without a single fin bent. It is the radiator shop's staple for a reason no alternative has ever displaced.

Strong acid means strong rules: never zinc or cadmium plate, watch immersion times, and rinse thoroughly. The Pro variant (pH 6) exists for exactly the assemblies that fail those rules.

Applications

Where it earns its keep

Radiator and core descaling; protein soils in food-plant hardware.

AutomotiveMiningFood & Beverage
Material caution: Strongly acidic: never on zinc, cadmium-plated or acid-sensitive alloys.
Temperature & Dose
SWEET SPOT 50 °C40–60 °C20 °C100 °C

Dose: 10–30%. The trial sets your exact process values; the TDS governs.

Run It Right

The working process

Why Flash Rust Happens

A freshly cleaned ferrous part is chemically active — protective films gone, surface warm and wet, rinse ions acting as electrolyte. Rust bloom can start within the hour. DI water rinsing slows it; protection stops it.

Protect It

Inhibitor in the final rinse before hot-air drying, an Anti-Rust dip between processes, or a water-displacing film for storage — matched to the next process. Tell us what happens next and the protection specifies itself.

The CoreKleen Family

Right product, right job

Buy CoreKleeninc GST
5 L$ TBC
20 LPOA
200 LPOA
Complete The Job
Anti-RustProtect the freshly bared metalView & buy →Rinse AidSpot-free final rinseView & buy →
Compatibility
Mild & carbon steelSulfamic acid — time-limit cycles, flash-rust risk
Stainless steelSafe in prescribed use
Cast ironSafe in prescribed use
Aluminium & titaniumDo not use
Magnesium & soft alloysDo not use
Zinc & galvanisedDo not use
Copper & brassSafe in prescribed use
Plated finishes (Cd·Cr·Ni)Do not use
Plastics & rubbersSafe in prescribed use
Painted / coated surfacesMay dull coatings — test first
Per prescribed use — the cleaning trial confirms on your parts; the TDS governs. Full range matrix →
Transport
TransportNot classified as Dangerous Goods for road and rail
No DG freight surcharge applies.
Bath Life

This is not a single-use chemical

A common misconception treats industrial chemistry like dishwater — used once, tipped out. A defended bath of CoreKleen works for weeks of production: weir oil separation and filtration defend the bath, solids leave through the filter, and the chemistry keeps working until genuine depletion.

Change out on evidence, not anxiety: when cycle times stretch or results fade at correct concentration, the bath has earned its retirement. Top-ups at specification carry it between changes.

Keep It Honest
  • Skim or weir oils continuously — oil load is bath killer #1
  • Filter solids; drain settled sludge from the sump
  • Verify concentration on schedule per the TDS check method
  • Log it — the trend predicts top-ups before cleaning fades
Storage

Drum and bath, both looked after

The Concentrate
  • Handling: Avoid eye contact and skin contact.
  • Avoid inhalation of vapour, mist or aerosols.
  • Storage: Store in a cool, dry, well-ventilated place and out of direct sunlight.
  • Store away from foodstuffs.
  • Store away from incompatible materials described in Section 10.
  • Store away from sources of heat and/or ignition.
  • Keep container standing upright.
  • Keep containers closed when not in use - check regularly for leaks.
  • This material is a Scheduled Poison Schedule 6 (Poison) and must be stored, maintained and used in accordance with the relevant regulations.
Compliant with the product SDS.
The Working Bath

Lid the tank between shifts — holds temperature, limits evaporation, keeps dust out.

Idle periods: a warm, stagnant aqueous bath can support biological growth over extended stagnation. Circulate periodically, keep concentration at specification, never leave an open tank standing for weeks.

Extended shutdown: drain to sealed, labelled containers — or schedule changeover for restart day.

Documents & Safety

The paperwork, on the page

Safety Data Sheet (SDS)
CoreKleen — Australian GHS SDS for your chemical register and risk assessments. PDF, 197 KB.
View SDSDownload
Technical Data Sheet (TDS)
Properties, composition, dose and compatibility at a glance. PDF, 80 KB.
View TDSDownload
Hazard identification
WARNINGPer Safe Work Australia GHS 7
Irritation - Category 2Irritation - Category 2A
Hazard statements
H315Causes skin irritation.
H319Causes serious eye irritation.
Key precautions
P102Keep out of reach of children.
P103Read carefully and follow all instructions.
P264Wash hands, face and all exposed skin thoroughly after handling.
P280Wear protective gloves/protective clothing including eye/face protection.
P101If medical advice is needed, have product container or label at hand.
P302+P352IF ON SKIN: Wash with plenty of water and soap.
Compliant with the product SDS — full document available for your chemical register.
PPE & exposure controls
  • National occupational exposure limits: No value assigned for this specific material by Safe Work Australia.
  • Biological Limit Values: As per the "National Model Regulations for the Control of Workplace Hazardous Substances (Safe Work Australia)" the ingredients in this material do not have a Biological Limit Allocated.
  • Engineering Measures: Natural ventilation should be adequate under normal use conditions.
  • Personal Protection Equipment: RUBBER BOOTS, OVERALLS, GLOVES, APRON, FACE SHIELD.
  • Personal protective equipment (PPE) must be suitable for the nature of the work and any hazard associated with the work as identified by the risk assessment conducted.
  • Wear rubber boots, overalls, gloves, apron, face shield.
  • Available information suggests that gloves made from nitrile rubber should be suitable for intermittent contact.
  • However, due to variations in glove construction and local conditions, the user should make a final assessment.
  • Always wash hands before smoking, eating, drinking or using the toilet.
  • Wash contaminated clothing and other protective equipment before storing or re-using.
Compliant with the product SDS — full document available for your chemical register.
First aid
  • If poisoning occurs, contact a doctor or Poisons Information Centre (Phone Australia 131 126, New Zealand 0800 764 766).
  • Inhalation: Remove victim from exposure - avoid becoming a casualty.
  • Remove contaminated clothing and loosen remaining clothing.
  • Allow patient to assume most comfortable position and keep warm.
  • Keep at rest until fully recovered.
  • Seek medical advice if effects persist.
  • Skin Contact: If skin or hair contact occurs, immediately remove contaminated clothing and flush skin and hair with running water.
  • Continue flushing with water until advised to stop by the Poisons Information Centre or a Doctor; or for 15 minutes and transport to Doctor or Hospital.
  • Eye contact: If in eyes, hold eyelids apart and flush the eyes continuously with running water.
  • Continue flushing until advised to stop by the Poisons Information Centre or a Doctor; or for at least 15 minutes and transport to Doctor or Hospital.
Compliant with the product SDS — full document available for your chemical register.
Storage & handling
  • Handling: Avoid eye contact and skin contact.
  • Avoid inhalation of vapour, mist or aerosols.
  • Storage: Store in a cool, dry, well-ventilated place and out of direct sunlight.
  • Store away from foodstuffs.
  • Store away from incompatible materials described in Section 10.
  • Store away from sources of heat and/or ignition.
  • Keep container standing upright.
  • Keep containers closed when not in use - check regularly for leaks.
  • This material is a Scheduled Poison Schedule 6 (Poison) and must be stored, maintained and used in accordance with the relevant regulations.
Compliant with the product SDS — full document available for your chemical register.
Disposal
  • Persons conducting disposal, recycling or reclamation activities should ensure that appropriate personal protection equipment is used, see "Section 8.
  • Exposure Controls and Personal Protection" of this SDS.
  • If possible material and its container should be recycled.
  • If material or container cannot be recycled, dispose in accordance with local, regional, national and international Regulations.
Compliant with the product SDS — full document available for your chemical register.
Transport & dangerous goods
  • Product Name: Corekleen Reference No: KT-CC-CK Issued: 2023-06-12 Version: 2.0 Safety Data Sheet ROAD AND RAIL TRANSPORT Not classified as Dangerous Goods by the criteria of the "Australian Code for the Transport of Dangerous Goods by Road & Rail" and the "New Zealand NZS5433:
  • Transport of Dangerous Goods on Land".
  • MARINE TRANSPORT Not classified as Dangerous Goods by the criteria of the International Maritime Dangerous Goods Code (IMDG Code) for transport by sea.
  • AIR TRANSPORT Not classified as Dangerous Goods by the criteria of the International Air Transport Association (IATA) Dangerous Goods Regulations for transport by air.
Compliant with the product SDS — full document available for your chemical register.
CoreKleen FAQ

Asked at the tank

What dilution and temperature do I run?
10–30% at 40–60 °C — and the trial sets your exact process values against your soil. Running richer than specified wastes chemical without cleaning faster. That range is the chemistry’s window — not the whole answer. The substrate sets its own ceiling, and it is usually lower: aluminium and anodised finishes discolour above about 65 °C, zinc and coated parts lower again, and magnesium is governed by pH before temperature. Run at the lower of the two. Bath temperature — chemistry vs substrate →
Why do my parts flash rust after cleaning?
Because the clean worked — protective films are gone and the bare metal is active. Rinse DI, then protect: in-rinse inhibitor, Anti-Rust dip, or a displacing film for storage.
When do I change the bath?
When cycle times stretch, results fade, or filtration stops holding the debris. Drain, clean the tank, refill — never lay fresh solution over settled sludge.
Will it attack my tank?
Acid work runs in tanks specified for it — 316 stainless or polymer, never bare mild steel. Misonics acid-duty tanks are built for exactly this; if you are retrofitting chemistry into an existing tank, confirm the tank material against the card before the first fill.
Can I get the SDS before buying?
Yes — every product ships with its SDS, and documents are available ahead of purchase for your chemical register and risk assessments.

Prove it on your parts

The trial pairs CoreKleen with your components — concentration, temperature and cycle documented before you order a drum. Wrong chemistry for your soil? The trial says so.

Talk to an engineer Back to the Range