Added to cart
NeutralTank Approved

Electro

Electronics cleaning without the fear

Water-based, non-flammable, formulated for populated boards — flux gone, components untouched.

Removes rosin, no-clean & water-soluble fluxesNon-flammable — no solvent compliance burden20–45 °C, trial-proven on sacrificial boards
From $121.00 inc GST
electro container
Machined steel components in a stainless mesh basket being lowered into an ultrasonic cleaning bath
The chemistry is half the process. It wets the tank and the part so cavitation can form at the surface, and it holds the soil once the ultrasound has lifted it.Illustration generated by Misonics.
Why It Wins

Electronics cleaning without the fear

Electronics cleaning used to mean solvents: flammable, regulated, and increasingly unavailable. Electro replaces them with water-based chemistry that removes rosin, no-clean and water-soluble flux residues — at 20–45 °C, non-flammable, with none of the vapour-management burden.

'No-clean' flux is the quiet trap it addresses: low-residue is not no-residue, and under humidity those residues become leakage paths and corrosion sites. Boards destined for conformal coating, RF service or long field life come off the line cleaner than their specification asks — cheaply.

Frequency, power and fixturing matter as much as chemistry on populated assemblies, which is why the electronics parameter set is proven on sacrificial boards in trial before production ever runs. Components that should be excluded get named before they get damaged.

Applications

Where it earns its keep

PCB rework and repair; connector and RF hardware; field-return electronics.

ElectronicsDefence
Temperature & Dose
SWEET SPOT 32 °C20–45 °C20 °C100 °C

Dose: Ready-formulated. The trial sets your exact process values; the TDS governs.

Run It Right

The working process

Precision Neighbours

Right product, right job

Buy Electroinc GST
5 L$121.00
20 LPOA
200 LPOA
Complete The Job
Rinse AidSpot-free final rinseView & buy →ZeroResidueFinal-stage cleanlinessView & buy →
Compatibility
Mild & carbon steelSafe in prescribed use
Stainless steelSafe in prescribed use
Cast ironSafe in prescribed use
Aluminium & titaniumMild alkaline — test on bare aluminium first
Magnesium & soft alloysTest first
Zinc & galvanisedSafe in prescribed use
Copper & brassSafe in prescribed use
Plated finishes (Cd·Cr·Ni)Safe in prescribed use
Plastics & rubbersSafe in prescribed use
Painted / coated surfacesSafe in prescribed use
Per prescribed use — the cleaning trial confirms on your parts; the TDS governs. Full range matrix →
Transport
TransportNot classified as Dangerous Goods for road and rail
No DG freight surcharge applies.
Bath Life

This is not a single-use chemical

A common misconception treats industrial chemistry like dishwater — used once, tipped out. A defended bath of Electro works for weeks of production: weir oil separation and filtration defend the bath, solids leave through the filter, and the chemistry keeps working until genuine depletion.

Change out on evidence, not anxiety: when cycle times stretch or results fade at correct concentration, the bath has earned its retirement. Top-ups at specification carry it between changes.

Keep It Honest
  • Skim or weir oils continuously — oil load is bath killer #1
  • Filter solids; drain settled sludge from the sump
  • Verify concentration on schedule per the TDS check method
  • Log it — the trend predicts top-ups before cleaning fades
Storage

Drum and bath, both looked after

The Concentrate
  • Handling: Avoid eye contact and skin contact.
  • Avoid inhalation of vapour, mist or aerosols.
  • Storage: Store in a cool, dry, well-ventilated place and out of direct sunlight.
  • Store away from foodstuffs.
  • Store away from incompatible materials described in Section 10.
  • Store away from sources of heat and/or ignition.
  • Keep container standing upright.
  • Keep containers closed when not in use - check regularly for leaks.
Compliant with the product SDS.
The Working Bath

Lid the tank between shifts — holds temperature, limits evaporation, keeps dust out.

Idle periods: a warm, stagnant aqueous bath can support biological growth over extended stagnation. Circulate periodically, keep concentration at specification, never leave an open tank standing for weeks.

Extended shutdown: drain to sealed, labelled containers — or schedule changeover for restart day.

Documents & Safety

The paperwork, on the page

Safety Data Sheet (SDS)
Electro — Australian GHS SDS for your chemical register and risk assessments. PDF, 209 KB.
View SDSDownload
Technical Data Sheet (TDS)
Properties, composition, dose and compatibility at a glance. PDF, 81 KB.
View TDSDownload
Hazard identification
WARNINGPer Safe Work Australia GHS 7
Irritation - Category 2Irritation - Category 2A
Hazard statements
H315Causes skin irritation.
H319Causes serious eye irritation.
Key precautions
P102Keep out of reach of children.
P103Read carefully and follow all instructions.
P262Do not get in eyes, on skin, or on clothing.
P264Wash hands, face and all exposed skin thoroughly after handling.
P280Wear protective gloves/protective clothing including eye/face protection.
P101If medical advice is needed, have product container or label at hand.
Compliant with the product SDS — full document available for your chemical register.
PPE & exposure controls
  • National occupational exposure limits: TWA STEL NOTICES ppm mg/m3 ppm mg/m3 (2-Methoxymethylethoxy) propanol 50 308 - - Sk Ethanolamine 3 7.5 6 15 - As published by Safe Work Australia.
  • TWA - The time-weighted average airborne concentration over an eight-hour working day, for a five-day working week over an entire working life.
  • STEL (Short Term Exposure Limit) - the average airborne concentration over a 15 minute period which should not be exceeded at any time during a normal eight-hour workday. ‘Sk' Notice - absorption through the skin may be a significant source of exposure.
  • The exposure standard is invalidated if such contact should occur.
  • These Exposure Standards are guides to be used in the control of occupational health hazards.
  • All atmospheric contamination should be kept to as low a level as is workable.
  • These exposure standards should not be used as fine dividing lines between safe and dangerous concentrations of chemicals.
  • They are not a measure of relative Product Name:
  • Electro Reference No: KT-CC-ELE Issued: 2023-05-01 Version: 1.1 Safety Data Sheet toxicity.
  • If the directions for use on the product label are followed, exposure of individuals using the product should not exceed the above standard.
Compliant with the product SDS — full document available for your chemical register.
First aid
  • If poisoning occurs, contact a doctor or Poisons Information Centre (Phone Australia 131 126, New Zealand 0800 764 766).
  • Inhalation: First aid is not generally required.
  • If in doubt, contact a Poisons Information Centre or a doctor.
  • Skin Contact: Wash gently and thoroughly with warm water (use non-abrasive soap if necessary) for 10-20 minutes or until product is removed.
  • Under running water, remove contaminated clothing, shoes and leather goods (e.g. watchbands and belts) and completely decontaminate them before reuse or discard.
  • If irritation persists, repeat flushing and seek medical attention.
  • Eye contact: Immediately flush the contaminated eye(s) with lukewarm, gently flowing water for 15 minutes or until the product is removed, while holding the eyelid(s) open.
  • Take care not to rinse contaminated water into the unaffected eye or onto the face.
  • Obtain medical attention immediately.
  • Take special care if exposed person is wearing contact lenses.
Compliant with the product SDS — full document available for your chemical register.
Storage & handling
  • Handling: Avoid eye contact and skin contact.
  • Avoid inhalation of vapour, mist or aerosols.
  • Storage: Store in a cool, dry, well-ventilated place and out of direct sunlight.
  • Store away from foodstuffs.
  • Store away from incompatible materials described in Section 10.
  • Store away from sources of heat and/or ignition.
  • Keep container standing upright.
  • Keep containers closed when not in use - check regularly for leaks.
Compliant with the product SDS — full document available for your chemical register.
Disposal
  • Persons conducting disposal, recycling or reclamation activities should ensure that appropriate personal protection equipment is used, see "Section 8.
  • Exposure Controls and Personal Protection" of this SDS.
  • If possible material and its container should be recycled.
  • If material or container cannot be recycled, dispose in accordance with local, regional, national and international Regulations.
Compliant with the product SDS — full document available for your chemical register.
Transport & dangerous goods
  • Not classified as Dangerous Goods by the criteria of the "Australian Code for the Transport of Dangerous Goods by Road & Rail" and the "New Zealand NZS5433:
  • Transport of Dangerous Goods on Land".
  • MARINE TRANSPORT Not classified as Dangerous Goods by the criteria of the International Maritime Dangerous Goods Code (IMDG Code) for transport by sea.
  • AIR TRANSPORT Not classified as Dangerous Goods by the criteria of the International Air Transport Association (IATA) Dangerous Goods Regulations for transport by air.
Compliant with the product SDS — full document available for your chemical register.
Electro FAQ

Asked at the tank

What dilution and temperature do I run?
Ready-formulated at 20–45 °C — and the trial sets your exact process values against your soil. Running richer than specified wastes chemical without cleaning faster. That range is the chemistry’s window — not the whole answer. The substrate sets its own ceiling, and it is usually lower: aluminium and anodised finishes discolour above about 65 °C, zinc and coated parts lower again, and magnesium is governed by pH before temperature. Run at the lower of the two. Bath temperature — chemistry vs substrate →
When do I change the bath?
When cycle times stretch, results fade, or filtration stops holding the debris. Drain, clean the tank, refill — never lay fresh solution over settled sludge.
Can algae grow in the bath if it sits unused?
Over extended stagnation, any warm diluted aqueous bath can support growth as preservative systems deplete. Prevention: circulate periodically, hold concentration at specification, lid the tank. If a bloom happens: drain, clean the tank including weir and lines with hot fresh solution, rinse and refill — never dose on top of growth.
Can I get the SDS before buying?
Yes — every product ships with its SDS, and documents are available ahead of purchase for your chemical register and risk assessments.

Prove it on your parts

The trial pairs Electro with your components — concentration, temperature and cycle documented before you order a drum. Wrong chemistry for your soil? The trial says so.

Talk to an engineer Back to the Range